Premium Australian commercial campus with office, education, secure and warehouse buildings at blue hour

KNX FOR COMMERCIAL BUILDINGS

One intelligent foundation. Every part of the building.

Lighting, climate, shading and building operations working together—across one room or an entire campus.

Choose a building to see what KNX changes.

OFFICES

Comfort where people are. Savings where they aren't.

Presence, daylight and schedules coordinate lighting, climate, blinds and meeting spaces while people retain simple local control.

WHAT PEOPLE EXPERIENCE Comfortable rooms, intuitive controls and lighting that responds naturally.
WHAT FACILITIES GAIN Actual occupancy insight, lower energy use and fewer after-hours surprises.
Explore offices
FOR ENGINEERSSee how KNX connects

BUILT AROUND THE BUILDING

See the building respond.

Select an environment, then change its operating scene. KNX connects each decision across the systems that need to respond.

Premium Australian office with open work areas and a glazed meeting room
Normal operation
LIGHTINGDaylight balanced
COMFORT22°C
OCCUPANCYActive zones

OFFICE

Every zone knows when it is needed.

Lighting, climate, shading and room status respond to presence, daylight and the way each space is actually used.

TRY AN OPERATING SCENE
WHAT PEOPLE EXPERIENCE

Comfortable workspaces, simple local control and meeting rooms ready for the activity taking place.

WHAT FACILITIES GAIN

Live zone status, operation matched to demand and fewer empty rooms consuming energy.

HOW THE BUILDING CONNECTS

See the physical wiring. Then follow the command.

KNX is the common control layer. Switches, sensors, room controllers, gateways and actuators all share the green KNX TP bus. Lighting then leaves the KNX–DALI gateway on its own DALI pair, while mains wiring remains separate.

THE IMPORTANT PART KNX is the shared control network—not a central hub.

Every KNX device joins the same green two-wire bus and exchanges addressed telegrams. The power supply energises the bus; normal room control does not depend on a server.

FOLLOW A REAL EVENT
PHYSICAL CONNECTIONS KNX control bus DALI control pair Mains / load wiring Ethernet / IP
IN THE ROOM SHARED GREEN KNX TP BUS IN THE DISTRIBUTION BOARD SEPARATE SYSTEMS & LOADS
KNX TP · two-wire bus power + telegrams
KNX 30 V DC power supply
KNX 30 V DC power supply

Supplies the KNX TP line with bus power.

VIEW PRODUCT →
DALI control pair
DALI lighting

DALI pair to drivers; mains power remains separate

KNX actuator
KNX actuator

Receives KNX telegrams and switches blind or relay outputs

VIEW PRODUCT →
Switched load
Blind motor

Switched load wiring from the KNX actuator

HV
KNX HVAC interface

Translates KNX setpoints and modes to the approved HVAC interface

Approved interface
HVAC system

Connected through an approved KNX/HVAC interface

1Home Server KNX Pro
1Home Server KNX Pro

Optional visualisation and automation layer, connected directly to KNX TP and Ethernet

VIEW PRODUCT →
Ethernet / IP
Apps, voice & integrations

Dashboards, scheduling, Matter ecosystems and remote access

KNX IP router
KNX IP router

Optional KNX TP connection to Ethernet for ETS or an IP backbone

VIEW PRODUCT →
Ethernet / IP
IP
ETS / KNX IP backbone

Engineering access and connection between KNX lines.

WHAT JUST HAPPENED 1. Wall switch → 2. KNX bus → 3. KNX–DALI gateway → 4. lights

The switch publishes a KNX group telegram. The KNX–DALI gateway receives it and sends the lighting command on the separate DALI pair. The light drivers remain separately mains powered.

01

The green cable links every KNX device

The KNX power supply, switches, sensors, room controllers, gateways, actuators and 1Home Server all connect to the same KNX TP bus. It carries bus power and telegrams and may use line, tree or star topology within KNX rules—not a ring.

KNX control bus
02

DALI begins at the KNX–DALI gateway

The gateway has KNX on one side and a separate DALI two-wire control pair on the other. DALI runs to drivers and luminaires; KNX switches and sensors do not sit on DALI.

DALI control pair
03

Power conductors are a separate layer

Protected mains circuits supply lighting drivers, motors and plant. KNX and DALI carry control information; neither replaces compliant power wiring, protection or the engineered electrical design.

Mains / load wiring

Representative topology only—not a construction wiring diagram. Cable selection, segregation, protection, topology limits and specialist-system interfaces must follow current standards, manufacturer instructions and the engineered project design.

DESIGNED FOR EVERY DECISION MAKER

The same system. A different advantage for each role.

Good building control must be buildable, commercially defensible and straightforward to operate for decades.

FOR ELECTRICAL ENGINEERS

A flexible control layer you can specify with confidence.

Use a proven open standard, coordinate services through defined interfaces and retain a clear path for extensions and long-term support.

  • Multi-vendor product choice
  • Scalable topology
  • KNX Secure options

WHY KNX

Specify a standard, not a dead end.

KNX is not just lighting control. It is an international building-control standard that lets compatible products from many manufacturers work together across disciplines.

01

An open international standard

Choose compatible devices from many KNX manufacturers instead of tying the building to one closed product family.

02

Distributed intelligence

Functions are shared across programmed devices, reducing dependence on one central proprietary controller for normal room operation.

03

Built to change with the building

Reconfigure scenes, schedules and zones through software, then extend the topology as floors, tenancies or services evolve.

04

Security designed into the specification

KNX Secure options can protect supported communication when selected, commissioned and managed correctly as part of the project security design.

START WITH THE OUTCOME

Planning a building that should work smarter?